Main products: oil filter, heater, electric heating drying room, high temperature heating furnace, drying room, oven, high power electric heater, oil bath heater, carbon fiber electric heater, quartz tube electric heater, high temperature electric heater, liquid heater other non-standard products
The size specification can be customized
Our classification only lists some conventional products, the price needs to be modified
Please consult Wangwang customer service
Call manager Zheng: 13761314297
We will according to your purchase quantity product specification to the specific price!
High efficiency vacuum oil filter is designed according to different boiling points of water oil. It is composed of vacuum heating tank, fine filter, condenser, primary filter, vacuum pump, oil drain pump electrical cabinet.
The vacuum pump of the high-efficiency vacuum oil filter draws out the air in the vacuum tank to form a vacuum. Under the action of atmospheric pressure, the oil the outside enters the primary filter through the inlet pipe to eliminate large particles, then enters the heating tank. The oil heated to 40-75 ℃ passes through the automatic oil level valve, which automatically controls the balance of the oil quantity entering the vacuum tank. The heated oil is separated into a semi mist by the rapid rotation of the spray wing. The water in the oil is rapidly evaporated into water vapor is continuously sucked into the condenser by the vacuum pump. The water vapor entering the condenser is cooled then discharged back to the original water. The oil in the vacuum heating tank is discharged into the fine filter by the oil discharge pump, the particulate impurities are filtered out through the filter element. Thus, the vacuum oil filter can quickly remove impurities, water gas in the oil, so that the clean oil can be discharged the outlet.
Preparation before use
1. Open the electrical box, check whether all electrical components are complete, whether they are loose wet, remove foreign matters.
2. Check whether the rotation direction of the motor is correct, which should conform to the direction of the indicating arrow.
3. Check whether the bolts nuts of each part of the machine are loose. Observe the oil window of vacuum pump whether the vacuum oil reaches the oil mark.
4. Connect the main power supply ground wire.
5. Close the drain valve of cooler, check whether the hose joints are loose, connect the inlet outlet pipes.
6. Check whether the coarse filter fine filter are installed properly.
7. Close all valves.
(2) Manufacturers start
1. Open the door of the electrical box, close the main power switch, adjust the temperature controller to 45-65 degrees;
2. Start the vacuum pump observe that the negative pressure of the vacuum gauge reaches the specified value (generally close to - 0.06mpa)
3. After the vacuum pump operates normally, open the oil inlet valve observe the oil level in the vacuum cylinder;
4. When the oil level reaches the lower window of the vacuum cylinder, start the oil drain pump, the heater can only be turned on when the oil circulates normally. When it starts to use, due to the humidity inside the machine the excessive moisture in the oil, a large amount of oil will be produced in the vacuum cylinder. At this time, the valve can be slightly opened to reduce the vacuum eliminate the foam. If the water content of turbine oil is too large, it is necessary to pay attention to the rise of oil foam in normal use. The oil foam shall exceed the upper window, so as to avoid entering the vacuum pump causing failure. After the machine runs normally, close the air inlet valve. In normal operation, both the rising of oil foam the vacuum degree should be controlled at - 0.08mpa.
(3) Operation precautions
1. The working temperature of vacuum pump shall exceed 75 ℃
2. When all motors work without abnormal noise, the motor temperature shall be greater than 60 ℃.
3. Pay attention to observe the pressure gauge. If the pressure gauge exceeds the specified value, stop the machine to clean the filter screen.
4. If the oil intake is too small, check the coarse filter whether the filter screen is blocked. If it is blocked, clean it with kerosene continue to use it.
(4) Precautions for shutdown:
The heater must be shut down first, then the vacuum pump should be stopped, then the oil inlet valve should be closed to discharge the tank
Technical parameters:
model
performance
XLDZJ
-30
XLDZJ
-50
XLDZJ
-75
XLDZJ
-100
XLDZJ
-125
XLDZJ
-150
XLDZJ
-200
XLDZJ
-300
work
ability
Flow rate L / min
Thirty
Fifty
Seventy-five
One hundred
One hundred twenty-five
One hundred fifty
Two hundred
Three hundred
Breakdown voltage kV
≥60
≥70
vacuum degree
≤0.098
Working pressure (MPA)
≤0.35
Working noise (DB)
≤70
≤75
≤80
Water content mg / kg
≤7
Air content%
≤0.3
Electric heating power kw
Fifteen
Fifteen
Twenty-four
Thirty-six
Forty-eight
Sixty
Seventy-two
Seventy-five
Total power kw
sixteen point five
Thirty-two
Thirty-two
Thirty-six
Fifty-six
sixty-seven point two
Eighty
Eighty
Supply voltage V
Three hundred eighty
In out diameter
DN25
DN32
DN48
DN50
DN60
Oil temperature range
30—60℃
Weight (kg)
Two hundred thirty
Three hundred forty
Three hundred ninety
Four hundred sixty
Five hundred twenty
Six hundred
Seven hundred fifty
Eight hundred
Overall dimension mm
Nine hundred
*750
*1150
one thousand two hundred
*900
*1450
one thousand four hundred
*1000
*1550
one thousand six hundred
*1100
*1700
one thousand seven hundred
*1100
*1800
one thousand seven hundred
*1100
*1800
one thousand eight hundred
*1200
*1900
one thousand nine hundred
*1200
*1900
The overall dimensions quality of the equipment are for reference only. With the continuous development of the products, the physical object shall prevail.
Parameter name
Company
YCL-20
YCL-30
YCL-50
YCL-75
YCL-100
YCL-150
YCL-200
YCL-300
flow
L/H
Twenty
Thirty
Fifty
Seventy-five
One hundred
One hundred fifty
Two hundred
Three hundred
Working vacuum
Mpa
-0.06~-0.096
working pressure
Mpa
≤0.5
Constant temperature control range
Temperature
20~80
Power Supply
V
380V / 50Hz (according to user requirements)
Working noise
dB(A)
≤78
heating power
KW
Fifteen
Eighteen
Twenty-four
Twenty-seven
Thirty-six
Forty-eight
Seventy-two
Ninety
Total power
KW
Nineteen
Twenty-two
Twenty-eight
Thirty-one
Forty
Fifty-two
Seventy-six
Ninety-six
Diameter of inlet outlet
Mm
Twenty-five
Twenty-five
Thirty-two
Thirty-eight
Thirty-eight
Fifty
Sixty-five
Sixty
Water content in oil
%
None (GB / T260)
Gas content in oil
%
≤0.1 (GB/T432)
Impurity machinery
%
None (GB / t511)
Filtration accuracy
Mu m
≤3